Open type incubated shaker
Features:
1. Well constructed for long term operation.
2. Advance technology ensuring mechanical stability and reliability of operation.
3. Shaking mechanism is constructed with chromium alloy material and high quality cast iron.
4. Circuit breaker protect against excess current, power-off memory to return to original setting, soft start prevents splashing, auto cut-off if motor overheat.
5. Precision microprocessor control system, accuracy of speed ± 1rpm.
6. Brushless high torque motor, maintenance free.
Â
Parameters:
Model |
HNY-810 |
HNY-820 |
HNY-850 |
HNY-880 |
Control mode |
P.I.D microcomputer processing chip |
|||
Oscillation mode |
convolution |
Reciprocate |
convolution |
Reciprocate |
Display |
LED digital display |
|||
Cyclotron frequency range |
30-300rpm/min |
|||
Cyclotron accuracy |
±1 |
|||
Shake plate shimmy range(mm) |
Ø26  |
|||
Max configuration |
100ml*22/250ml*12/500ml*8 |
250ml*92/500ml*66/1000ml*36(double) Â |
||
Standard configuration |
250ml*12 |
250ml*46(double) |
||
Plate size(mm) |
430*325 |
800*600 |
||
Plate number |
1 |
2(double) |
||
Size(mm) |
456*380*195 |
900*640*780(double) |
||
Power(w) |
80 |
200 |
||
Voltage |
AC220±10% 50-60HZ |
Vertical double-layer constant temperature shaking incubator
Summary:
This type of instrument is widely used in germ culture, ferment, hybridization, and research of biochemical reaction; enzyme and cellular tissue and all those require high temperature and oscillation frequency
Control feature:
Function of parameters memory and electricity incoming recovery when data lost because of power cut or system halted
Structure feature:
Sort: Microcomputer LCD type
Performance feature:
1.P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters.
2.The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations
3.AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free.
4.Overtemperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs.
5.Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off.
6.Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples.
7.The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window.
Parameters:Â
Model | HNY-1102C | HNY-2102C | HNY-1102 | HNY-2102 | HNY-1112B | HNY-2112B | HNY-1112F | HNY-2112F | |||||
Control mode | P.I.D microcomputer processing chip | ||||||||||||
Convection mode | Forced convection | ||||||||||||
Oscillation mode | convolution | Reciprocate | |||||||||||
Display | LCDÂ display | ||||||||||||
USB data download system | Yes | ||||||||||||
Kudan control system | Yes | ||||||||||||
Cyclotron frequency range | 30-300rpm/min | 30-280rpm/min | |||||||||||
Cyclotron frequency accuracy | ±1 | ||||||||||||
Shake plate shimmy range(mm) | Ø26 | Ø26(Ø35) | 0-50 | ||||||||||
Max configuration | 100ml*48/250ml*24/ 500ml*24 |
100ml*90/250ml*56/500ml*48 | 250ml*90/500ml*74/1000ml*36 | ||||||||||
Standard configuration | 250ml*24 | 250ml*28 500ml*22 |
250ml*45 500ml*36 |
||||||||||
Pallet size(mm) | 500*350 | 745*450 | 970*560 | ||||||||||
Timing(h) | 0-999 | ||||||||||||
Temp. range(ºC) | Ambient temp.+5-60 | 4-60 | Ambient temp.+5-60 | 4-60 | Ambient temp.+5-60 | 4-60 | Ambient temp.+5-60 | 4-60 | |||||
Temp.accuracy | ±0.1ºC | ||||||||||||
Temp. uniformity(ºC) | ≤0.5(37ºC) | ||||||||||||
Temp. fluctuation(ºC) | ≤0.2(37ºC) | ||||||||||||
Plate number | 2 | ||||||||||||
Size(mm) | 700*560*1260 | 950*700*1260 | 1200*820*1560 | ||||||||||
Volume(L) | 175 | 335 | 580 | ||||||||||
Power(w) | 600 | 850 | 900 | 1150 | 1100 | 1400 | 1100 | 1400 | |||||
Voltage | AC220±10% 50-60HZ | ||||||||||||
Ambient temp.(ºC) | 5-25 |
Â
Horizontal type incubator shaker series:
Summary:
This type of instrument is widely used in germ culture, ferment, hybridization, and research of biochemical reaction; enzyme and cellular tissue and all those require high temperature and oscillation frequency.
Control feature:
Function of parameters memory and electricity incoming recovery when data lost because of power cut or system
Structure Feature:Sort: Microcomputer LCD type
Performance feature:
1 P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters.
2 The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free.
3 Over-temperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs. Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off.
4 Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples. The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window. Use of microcomputer intelligent control system, powerful, strong anti-interference ability.
5 Can achieve the 1-24 time period of the day and night free combination of temperature and illumination parameters of ten sections of programming. Whole quiet design, electrostatic spray cabinet with tempered glass observation window, always observe the inside temperature and light conditions.
6 The top of the built-in light, special biological light source spectral characteristics, high strength, fever, particularly suitable for the experimental requirements
Parameters:
Model | HNY-111A | HNY-211A | HNY-111B | HNY-211B | HNY-111C | HNY-211C | HNY-111F | HNY-211F | |||
Control mode | P.I.D microcomputer processing chip | ||||||||||
Convection mode | Forced convection | ||||||||||
Oscillation mode | convolution | Reciprocate | |||||||||
Display | LCDÂ display | ||||||||||
USB data download system | Yes | ||||||||||
Kudan control system | Yes | ||||||||||
Lllumination | 4Â Â 12000LX(max) | No | |||||||||
Cyclotron frequency range | 30-300rpm/min | ||||||||||
Cyclotron frequency accuracy | ±1 | ||||||||||
Shake plate shimmy range(mm) | Ø26 | 0-50 | |||||||||
Max configuration | 100ml*66/250ml*45/ 500ml*28 100ml*18/2000ml*11 |
250ml*45/500ml*28/1000ml*18/2000ml*11/5000ml*6 | 250ml*46/500ml*33/1000ml*18 | ||||||||
Standard configuration |  500ml*28 |
2000ml*8 | 500ml*33 | ||||||||
Pallet size(mm) | 920*510 | 800*520 | |||||||||
Timing(h) | 0-999 | ||||||||||
Temp. range(ºC) | Ambient temp.+5-60 | 4-60 | Ambient temp.+5-60 | 4-60 | Ambient temp.+5-60 | 4-60 | Ambient temp.+5-60 | 4-60 | |||
Temp.accuracy | ±0.1ºC | ||||||||||
Temp. uniformity(ºC) | ≤0.5(37ºC) | ||||||||||
Temp. fluctuation(ºC) | ≤0.2(37ºC) | ||||||||||
Plate number | 1 | ||||||||||
Size(mm) | 1200*740*800 | 1200*740*1000 | 1200*740*800 | ||||||||
Volume(L) | 188 | 260 | 188 | ||||||||
Power(w) | 1100 | 1300 | 650 | 900 | 650 | 950 | 650 | 900 | |||
Voltage | AC220±10% 50-60HZ | ||||||||||
Ambient temp.(ºC) | 5-25 |
Table-top type shaking incubator
Control Feature:
Function of parameters memory and electricity incoming recovery when data lost because of power cut or system halted.
Structure Feature:
Sort: Microcomputer LCD type
Performance Feature:
1.P.I.D environmental scanning micro-processing controller and intelligentized audio and visual alarm,The large LCD screen clearly indicates the preset and real parameters.
2.The operating parameter locked by encryption prevents misoperation.7.Operating parameter memory function avoids monotonous operations
3.AC inductive long-life motor design, broad speed regulation, constant torque, constant speed of rotation, no carbon brush and maintenance free.
4.Over-temperature audio and visual alarming function can automatically cut off the power when the motor overheated, temperature out of control or abnormal temperature occurs.
5.Provided with power-off recovery function, the equipment can automatically recover to run according to the originally designed programs when the external power is recovered after a sudden cut off.
6.Wiring of the acceleration control ensures soft start, smooth acceleration and the security of samples.
7.The luxurious streamline mould involving aesthetic designing, static plastic-spraying case and large toughened glass window.
 Parameters:
Model |
HNY-209 |
HNY-100B |
HNY-100D |
HNY-200B |
HNY-200D |
Control mode |
P.I.D microcomputer processing chip |
||||
Convection mode |
Forced convection |
||||
Oscillation mode |
convolution |
||||
Display |
LED digital display |
LCD display |
|||
USB data download system |
No |
Yes |
|||
Cyclotron frequency range |
40-500rpm/min |
30-600rpm/min |
|||
Cyclotron frequency accuracy |
±1rpm |
||||
Shake plate shimmy range(mm) |
Ø26  |
Ø26  |
Ø0-50  |
Ø26  |
Ø0-50  |
Max configuration |
50ml*16/100ml*10/ 250ml*8 |
100ml*23/250ml*12/500ml*9/1000ml*5 |
|||
Standard configuration |
50ml*4/100ml*3/ 250ml*3 |
500ml*3Â 250ml*3 100ml*4Â Â 50ml*4 |
500ml*3Â 250ml*4 100ml*5Â Â 50ml*5 |
||
Pallet size(mm) |
220*280 |
450*410 |
410*360 |
450*410 |
410*360 |
Timing(h) |
0-166 |
0-999 |
|||
Temp.range(°C) |
10-60 |
Ambient temp.+5-60 |
4-60 |
||
Temp. accuracy(°C) |
±0.1 |
||||
Temp. uniformity(°C) |
≤0.5(37°C) |
||||
Temp. fluctuation(°C) |
≤0.2(37°C) |
||||
Pallet number |
1 |
||||
Size(mm) |
550*510*440 |
740*710*510 |
|||
Volume(L) |
26 |
70 |
|||
Power(w) |
300 |
550 |
650 |
650 |
650 |
Voltage |
AC220±10% 50-60HZ |
||||
Ambient temp. |
5-25 |
Â
Open type incubated shaker
Features:
1. Well constructed for long term operation.
2. Advance technology ensuring mechanical stability and reliability of operation.
3. Shaking mechanism is constructed with chromium alloy material and high quality cast iron.
4. Circuit breaker protect against excess current, power-off memory to return to original setting, soft start prevents splashing, auto cut-off if motor overheat.
5. Precision microprocessor control system, accuracy of speed ± 1rpm.
6. Brushless high torque motor, maintenance free.
Â
Recycle Plastic Machine,Plastic Sorting Machine,Mixed Plastic Separator,Plastic Waste Recycling Machine
Xinxiang Traceability Environmental Protection Equipment Co., Ltd. , https://www.syrecycle.com