Basic use of multi-element analysis instruments

First, the connection and power supply of the instrument Connect the mains power socket to the mains with the power cable, and ground the instrument reliably (otherwise it is easily disturbed and cause data fluctuations); Check whether the drainage hose is firmly installed (do not put the liquid hose The end of the outlet is not in the waste liquid, so as not to discharge the liquid). Inject distilled water (reference liquid) into the cuvette and turn on the power switch of the instrument. At this time, the heat number is displayed. If you need to modify, press a digit key and press The “Execute” button ends and the channel shows the concentration value. After the power is stable for 10 to 15 minutes, zero input and full-scale adjustment can be performed.

Second, zero input and full-scale adjustment In the daily use of the instrument, it is necessary to adjust the zero and full-scale work, the general zero does not need to be adjusted frequently, and can be adjusted once after each power-on.

Press the channel key, the channel digital tube's sign bit shows “U”, the remaining 4 digits show the signal percentage (transmittance U), press the zero ammonium button (sometimes sound), the zero point is input and stored Get up, then press the zero knob to return to normal. Adjust the channel full-scale adjustment knob so that the percentage of the signal is displayed as about 100.0. Press the full-scale button again and the full-scale will be tracked to 100.0. After the channel zero input and full-scale adjustment is completed, press the “EXIT” button.

The Filter

Working principle of precision filter

Precision filter is mainly composed of filter container, support basket and filter bag these three parts. It's made of stainless steel. Flange precision filter is divided into 1,2,3 and 4 filter bags according to the size of the filter bag. Liquid inlet and outlet direction is divided into side in bottom out type and bottom in bottom out type.

When the precision filter is working, the liquid enters the filter bag supported by the supporting mesh frame from the interface. The filter bag will be evenly expanded to the periphery by the impact of the liquid, so that the liquid can be evenly distributed on the inner surface of the whole filter bag. The liquid passes through the filter bag and is discharged from the outlet at the bottom of the filter. The filter residue is left to be intercepted in the filter bag.

When the filter bag can be replaced after running for a long time, or when the pressure difference between the inlet and outlet reaches 0.05-0.07mpa during use, the filter bag also needs to be replaced.

Stainless steel mechanical filter,Activated carbon filter,Pre-filter tank for water treatment